        Nanjing Hotel washing machine ironing washing equipment, Suzhou industrial washing machine, washing equipment, washing equipment, large-scale clothing washing machine, washing machine is used for a long time, due to mechanical wear, lack of lubrication oil, aging, mechanical spring fatigue deformation and other reasons, there will be all kinds of abnormal vibration and noise. If not timely repair, will lead to mechanical washing machine accelerated wear or damage. In fact, through the appropriate adjustment and simple repair, which can eliminate or reduce the vibration and noise.  
        1, when washing clothes, body issued a "bang" sound. The fault is generated between the collision or washing barrel and the casing are washing machine placed ground formation or four feet with the ground to maintain good contact. This will be the focus of washing machine adjustment, stable placement, or in the four bottom mat on the appropriate block.  
        2, when washing clothes, the impeller rotation issued "giggle" friction sound. Maintenance, can be put into the water, do not put the clothes to check. If in the impeller rotates still "friction sound chuckle", the description is due when the impeller rotation with the washing barrel at the bottom of the friction caused by clothing, such as add, the noise will be greater. Failure may be due to the impeller screw loosening, can now remove out of the impeller, and then end with pad suitable thickness in shaft bottom gasket, to increase the clearance of the impeller and the bottom of the barrel. The elimination of both the collision or friction. If the impeller outer ring rubbing washing barrel, should remove the impeller, re installed after dressing.  
        3, the motor rotates, the rotating belt issued a "crackling" sound. The fault is caused due to the transmission belt relaxation. Overhaul, the motor frame fastening screws, the rotation of the motor to away from the impeller axis direction, the drive belt tension, then tighten the fastening screw machine. Faults: into the water does not reach the set water level when you stop the water.
        analysis and maintenance of: this fault is the main adverse pressure switch performance, so that the gas chamber in air pressure has not yet reached the specified pressure, the contact is advanced by the off state to a closed state and stop water inlet, the specific reasons and treatment methods are: (1) water switch for water level control of the spring the pre compression becomes small, as long as the screw in the adjusting screw to increase the water level control of the spring pre compression can be solved. If the water level control spring decreases or loses the elasticity, is to replace the water level control spring. (2) the water pressure switch on the cam groove wear or damage, the general to replace cam can solve.
        fault two: the amount of water must be more than the set water level more will stop water.
        analysis and maintenance of: this phenomenon indicates that the actual water level has reached the required height, hydraulic pressure switch in the air of the air chamber pressure is still not up to the specified value, only to continue raising water level, water pressure switch will move. Specific reasons and treatment methods are: (1) water switch gas collecting chamber air guide joint nozzle blockage or leakage. As long as the scavenging air guide connecting mouth sundry; or the leak department with 401 rubber sealing can. If the air guide hose aging kink or rupture leak, to replace the air guide hose. (2) the water switch for water level control of the spring pre compression is too large. As long as the adjusting screws are screwed out some, reducing the water level control spring pre compression can be. (3) reversing push rod and transmission components in a water switch deformation or damage. Through the repair correction to solve, serious is to replace the water pressure to open the service hotline: 18796738388